๐Ÿ“ž+86 159 5113 7160
โœ‰info@jblmetal.com
Language
Third-Party Certification

SGS Salt
Spray Test

Independent Corrosion Verification

JBL Metal's stainless steel mesh systems are independently tested by SGS Group under the neutral salt spray protocol. The results verify corrosion resistance performance for coastal, marine, and high-humidity exterior applications โ€” documented by a third party, not self-declared.

Certification Reference
Testing BodySGS Group
Test StandardISO 9227 ยท Neutral Salt Spray
Grades TestedSS304 ยท SS316
Treatments TestedAcid Pickled ยท Electropolished
Certification TypeThird-Party ยท Independent
RelevanceCoastal ยท Marine ยท High Humidity
SGS
Independent
Testing Body
ISO
9227 ยท Neutral
Salt Spray Standard
3rd
Party Verified
Not Self-Declared
Grade+
Countries
Accepted
What the Test Is

Neutral Salt
Spray Test โ€”
ISO 9227

The test creates an accelerated corrosion environment that simulates years of coastal exposure in a controlled number of hours. It removes the variable of real-world exposure time from the specification equation.

The neutral salt spray test (NSS) exposes metal specimens to a continuous saline fog โ€” 5% sodium chloride solution at 35ยฐC โ€” for a defined exposure duration. At specified intervals, specimens are examined and the time to first corrosion onset, corrosion area, and corrosion severity are recorded.

The test does not simulate a specific geographic environment. It creates a standardised, reproducible accelerated corrosion condition that enables direct comparison between grades, surface treatments, and manufacturers โ€” without waiting years for real-world exposure data.

Test Condition
5% NaCl ยท 35ยฐC

Standardised saline fog concentration and temperature per ISO 9227. Continuous exposure throughout the test duration. No cycling โ€” constant aggressive environment.

What Is Measured
Time to First Corrosion

Hours to first visible corrosion onset (rust staining, pitting, or blistering) on the specimen surface. Also recorded: corrosion area percentage at specified intervals and post-test surface condition.

Testing Body
SGS Group โ€” Independent

SGS Group is one of the world's largest independent testing, inspection, and certification organisations. Test results issued by SGS carry international recognition and are accepted by specifiers, architects, and building authorities across 50+ countries.

Why Third-Party
Not Self-Tested

JBL Metal's corrosion performance data is not produced by internal testing. SGS conducts the test independently โ€” the result cannot be adjusted, selected, or influenced by the manufacturer. This is the distinction between a specification claim and verified evidence.

What the Results Show

Grade & Treatment Performance Comparison

The SGS test results document the corrosion performance difference between grades and surface treatments at the same exposure duration โ€” not just a single grade pass/fail. This enables correct grade selection for project-specific environments.

GradeSurface TreatmentPerformance ClassRecommended EnvironmentNotes
SS304Acid Pickled & PassivatedGoodInland exterior ยท Urban ยท InteriorStandard specification for non-coastal applications. Not for direct coastal exposure.
SS304Electrolytic PolishedGood+Inland exterior ยท Mild coastal (5โ€“10km)Electropolish improves SS304 corrosion resistance. Still not a substitute for SS316 in aggressive coastal environments.
SS316Acid Pickled & PassivatedExcellentCoastal (<5km) ยท Industrial ยท High humidityMolybdenum addition gives SS316 significantly higher chloride resistance. The minimum specification for coastal facades.
SS316Electrolytic PolishedSuperiorMarine ยท Harbour ยท Severe coastalElectropolished SS316 achieves the highest corrosion performance in JBL Metal's tested range. Required for <1km ocean proximity.

The test result is not a marketing claim. It is a data point. The specifier decides what that data means for their project environment โ€” we provide the evidence.

When to Specify

Projects That
Require Corrosion
Documentation

Not every project requires third-party corrosion certification. The following conditions are where SGS test documentation is typically requested โ€” or should be proactively provided.

Coastal & Marine Facades
Within 5km of the Ocean

Facade specifications for buildings within 5km of the ocean in Oceania and internationally routinely require corrosion performance documentation. SGS test data satisfies this requirement and supports NCC durability compliance submissions.

Public Infrastructure
Bridges ยท Terminals ยท Stations

Public infrastructure projects โ€” particularly transport terminals, waterfront structures, and bridges โ€” commonly include material performance specifications that require documented third-party testing rather than manufacturer data sheets alone.

Specified Durability Requirements
50-Year Design Life Projects

Projects specifying 50-year design life, commercial warranty requirements, or institutional procurement standards often require corrosion performance evidence as part of the tender documentation package. SGS certification is accepted across these frameworks.

OEM Product Certification
Component-Level Certification

OEM equipment manufacturers incorporating JBL Metal mesh into certified product assemblies may require component-level corrosion testing as part of their own certification process. SGS test documentation is available for inclusion in OEM technical files.

Requesting Documentation

How to Obtain the SGS Test Report

The SGS test certificate and full test report are available for submission with project drawings. They are provided as project documentation โ€” not attached to catalogue product listings.

01
Submit Your Project Drawings

Use the drawing submission form. Include the project location (for environment assessment) and note that SGS certification documentation is required for the specification package.

Submit Drawings →
02
Receive System Recommendation

Within 6 business hours, we will recommend the correct grade and surface treatment for your project environment โ€” with the SGS test results for the specified combination included.

03
Documentation Package Issued

The SGS certificate, full test report, material grade specification, and surface treatment confirmation are issued in writing as a project documentation package โ€” suitable for tender submission.

SGS Certification

Request the
Test Report for
Your Project

Submit your project drawings and location. We will identify the correct material grade for your environment and issue the SGS salt spray test documentation โ€” certificate, full test report, and written specification โ€” within 6 business hours. Everything in writing.